New Track 2-7
Installation
Isolation Interface to Starters Box Interface Wiring
*Isolation Interface Drawing A-56252
**Start Line Interface Drawing A-72242
Isolation Interface to Start Line J-Box
Description From (I/I)* Cable
Specification
Wire Color To (SLJB)** Function
TB7-1 Red TB3-1 LPSTAGEPCL-P
TB7-2 Black TB3-7 LPSTAGEPCL-N
Pre-Stage
Left Lane
TB7-3
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
TB7-4 Red TB3-2 LSTAGEPCL-P
TB7-5 Black TB3-7 LSTAGEPCL-N
Stage Left Lane
TB7-6
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
TB7-7 Red TB3-3 LGUARDPCL-P
TB7-8 Black TB3-7 LGUARDPCL-N
Guard Left Lane
TB7-9
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
TB1-1 Red TB3-4 RPSTAGEPCL-P
TB1-2 Black TB3-8 RPSTAGEPCL-N
Pre-Stage Right
Lane
TB1-3
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
TB1-4 Red TB3-5 RSTAGEPCL-P
TB1-5 Black TB3-8 RSTAGEPCL-N
Stage Right Lane
TB1-6
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
TB1-7 Red TB3-6 RGUARDPCL-P
TB1-8 Black TB3-8 RGUARDPCL-N
Guard Right Lane
TB1-9
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
TB16-1 Red TB1-1 SIG3-P
TB16-2 Black TB1-2 SIG3-N
Tree Signal
TB16-3
Beldon 8760
(Dak W-1117)
Shield No Connection Shield-N
Refer to the Operational Check (Section 2.8) for connection and power up procedure.
*Isolation Interface
**Start Line Junction Box
Note: If field cabling for guard beam photocells is present, but guard beam
photocells are not used, do not connect unused guard beam cabling to the isolation
interface terminal blocks (TB7-7, TB7-8, TB7-9, LGUARDPCL, and TB1-7, TB1-8,
TB1-9, RGUARDPCL).
Description Form (I/I)*
Cable
Specifications
Wire Color To (SLI)** Function
TB 13-1 Red Trans + Rec-P
TB 13-2 Black Trans - Rec-N
TB 13-3 Shield Not Connected Earth
TB 13-4 Green Rec + Trans-P
TB 13-5 White Rec - Trans-N
Isolation Interface/
Start line Interface
Communications
TB 13-6
Manhattan u4473
(Dak W-1234)
N.C. Not Connected Earth