Item Part No. # Part No. # Part No. # Part No.
1 0A-1067-0128 11 W-1267 21 0A-1067-0108 31 Incl. w/item #28
2
Incl. w/item
#1
12 W-1117 22 0A-1067-0111 32 A-1157
3 A-1305 13 0A-1067-0099 23 0A-1067-0064 33 0A-1081-0016
4 A-1157 14 0A-1067-0100 24 0A-1067-0065 34 Custom
5 W-1239 15 W-1399 25 0A-1067-0063 35 Custom
6 0A-1067-0076 16 0A-1067-0010 26 W-1117 36 0A-1067-0143
7 W-1266 17 0A-1081-0146 27 0A-1067-0080 37 W-1117
8 W-1266 18 W-1237 28 0A-1067-0050 38 EC-1082
9 W-1264 19 0A-1067-0107 29 W-1350 39 A-1078
10 W-1267 20 0A-1067-0071 30 A-1305 40 Custom
2.6 Location Requirements
Reference Drawings:
Field Cabling; C-44 Timer ...........................................................Drawing B-75554
This section explains the equipment locations on the track for best operation. Such topics as
conduit, power and electrical requirements, noise levels, and other location considerations are
discussed. Daktronics recommends that these guidelines be followed as closely as possible.
Signal Conduit and Cable
All cable should be 18 awg twisted shielded pair, Beldon 8760 (Dak W-1117) unless
noted. All cable should be in conduit. Refer to Drawing B-75554 for conduit sizes and
cable types.
Power
The following is a list of electrical items and their respective power requirements.
Unit Power Requirement (Watts)
Start line outlet 100
Tower outlets 1800
C-44 console 100
Color monitor (C-44) 114
Isolation interface 30
Printer (log or time slip) 30
Time slip printer booth outlet 84
60 ft. line outlet 200
1/8th mile line outlet 30
Starters box interface 100
Color monitor (results) 102
DAKTRONICS 486DX computer 100
Three-amber tree 2000 (min 20 amps)