4-6
4.5 Operation Summary
Function # Description Range
1 Display Frame Duration 2-9 Seconds
2 Display Sequences
T = Time
F = Fahrenheit
C = Celsius
P1 = Price #1
P2 = Price #2
Note: Sequences 8 - 20 are not available in 8/7 segment
mode.
Selections 0-20
0 = F, C 11 = P1, C
1 = T, F 12 = P1, T, F
2 = T, C 13 = P1, T, C
3 = T, F, C 14 = P1, T, F, C
4 = T, F, T, C 15 = P1, P2
5 = T 16 = P1, P2, T
6 = F 17 = P1, P2, T, F
7 = C 18 = P1, P2, T, C
8 = P1 19 = P1, P2, T, F, C
9 = P1, T 20 = Lampbank Test
10 = P1, F
3 Dimming 0: Automatic
1: Bright
2: Dim
4 Font Select 0: Block
1: Rounded
5 Temperature Offset -9 to +9 degrees F
6 Temperature Indicator 0-3
Value
Temp.
Displayed
Indicator
Displayed
0
F
C
blank
“c”
1
F
C
degree
“c”
2
F
C
“F”
“C”
3
F
C
“F”
degree
7 Start Up Time - Hours 0-23
8 Start Up Time - Minutes 0-59
9 Shut Down Time - Hours 0-23, 99 (disable)
10 Shut Down Time - Minutes 0-59
11 Day of Week 1-7
12 Date 1-31
13 Month 1-12
14 Year 90-99, 00-20